Skip to content

Request a Quote

Scan Heads

QS-12 OPD Open Frame 2-Axis Scan Head

For fast, accurate beam steering in XY applications

Open Frame 2-Axis Scan Heads are used for fast and accurate XY beam steering. Open frame heads are compact and provide flexibility for mounting in OEM applications or products.

  • Recommended apertures10mm, 15mm & 20mm
  • Product familyOpen Frame 2-Axis Scan Heads
Nutfield Tech's QS-7 OPD Open-Frame Scan Head

Overview

Nutfield Technology’s open frame scan heads include two galvanometers with mirrors mounted in optimized XY configuration, two servo amplifiers (require mounting to heat sink, not provided), and galvo-to-servo cable sets.

Nutfield Tech’s QS-12 XY Open Frame Scan Heads feature factory-set  ±5 or ±10VDC analog inputs that produce ±22.5 degrees optical scan angles.  The QS-12 OFH is available in 10mm, 15mm, and 20mm apertures for a variety of wavelengths.

Contact Nutfield Technology for assistance with identifying a solution for your scanning application.

Key Features

Key features of the QS-12 OPD Open Frame Scan Head:

  • 10mm to 20mm aperture range
  • DAC and function generator solutions available
  • Available match-tuning ensures same X & Y galvo response given the same input command
  • Offers a strong combination of performance and value
  • XY Receiver Card available for interface with Nutfield’s WaveRunner Scan Control Software and SurfBoard or Pipeline Scan Control Hardware

Specifications

Values as published by Nutfield Technology.

Specifications for the QS-12 OPD Open Frame Scan Head:

Specifications:Value
QS-12 OPD Open-Frame Scan Head
Performance:
Linearity>99.8% @ ±20°
Gain Drift50ppm/°C
Offset Drift15 µrad/°C
Repeatability10 µrad
Dynamic Performance:
Step Response Time
10mm X Mirror350 µs
10mm Y Mirror Match420 usec
15mm X Mirror600 µs
15mm Y Mirror Match720 usec
20mm X Mirror650 usec
20mm Y Mirror Match780 usec
Cable lengths available:7″ to 24″ (0.18m to 0.61m)
Storage Temperature:10 to 50°C
Operating Temperature:0 to 40°C noncondensing
All specifications are using Nutfield Tech’s QD-4000 Servo Amplifier.

Applications

Nutfield’s QS-12 OPD Open Frame Scan Heads are ideal for the following applications:

  • Microscopy
  • Optical Coherence Tomography (OTC)
  • Marking
  • Materials Processing
  • Imaging

Accessories

Accessories available for the QS-12 OPD Open Frame Scan Head:

  • Cables – available lengths 7″ to 24″ (0.0178m to 0.610m)

Downloads

Documentation for the QS-12 OPD Open Frame Scan Head:

Need help choosing the right scanning solution?

Contact Nutfield Technology for assistance with identifying a solution for your scanning application.