Galvanometer Scanners
QS-3 OPD Galvanometer Scanner
Lightweight and extremely compact; ideal for hand-held applications
The QS-3 OPD moving-magnet galvanometers are lightweight and extremely compact. They are ideal for hand-held scanning applications. Our mechanical design incorporates our exclusive ceramic ball-bearing motors that are combined with our high output position detectors. Patented low inertia optical detectors achieve dynamic performance with faster, more accurate positioning. When integrated with Nutfield’s QD-4000 servo amplifier, the QS-3 OPD scanners deliver accuracy and speed in the palm of your hand.
- Recommended apertures3mm, 5mm
- Product familyOptical Position Detector Galvos

Overview
Contact Nutfield Tech for assistance with identifying a solution for your scanning applications.
Key Features
Key features of the QS-3 OPD Galvanometer Scanner:
- 3mm and 5mm apertures
- 200 µs Step Response with 3mm aperture mirror; 250 µs with 5mm aperture mirror
- Lightweight, smaller and faster than standard galvos
- Low drift – 50ppm
- High Linearity – 99.8%
- High Resolution
- Excellent RF noise immunity
- Available as galvanometer, single-axis scanner or XY Scan Set
Specifications
Values as published by Nutfield Technology.
Specifications for the QS-3 OPD Galvanometer Scanner:
| Specifications: | Value |
|---|---|
| Standard Specifications: | QS-3 OPD Galvanometer Scanner |
| Rotor Inertia | 0.008 gm-cm² |
| Torque Constant | 12,000 dyne-cm |
| Coil Resistance | 1.8 ohm |
| Coil Inductance (@ 1kHz) | 26 µh |
| Weight (without cable) | 19.6 g |
| Inertial Load: | |
| Recommended | 0.01 gm-cm² |
| Maximum | 0.04 gm-cm² |
| Position Detector: | |
| Linearity* | >99.8% @ ±20° |
| Gain Drift | 50 ppm/°C |
| Offset Drift | 15 µrad/°C |
| Repeatability | 10 µrad |
| Typical output signal | |
| differential mode | 14.5 µA/° |
| common mode | 151 µA |
| Supply current | 15 – 20 mA |
| * For larger angles, contact Nutfield Tech. | |
| Dynamic Performance: | |
| Step Response Time | |
| (1% of full scale, 99% settled) | |
| 3mm X Mirror | 200 µs |
| 5mm X Mirror | 250 µs |
| Cable lengths available: | 7″ to 24″ (0.18m to 0.61m) |
| Storage Temperature: | 10 to 50°C |
| Operating Temperature: | 0 to 40°C noncondensing |
| All specifications are using Nutfield Tech’s QD-4000 Servo Amplifier. |
Applications
Use the QS-3 OPD Galvanometer Scanner to support the following applications:
- Optical Coherence Tomography (OTC)
- Biomedical Imaging
- Imaging
- Microscopy
- High Speed Scanning
- Laser Light Show and Projection
- Dental Ablation
Accessories
Accessories available for the QS-3 OPD Galvanometer Scanner:
- Cables – available lengths 7″ to 24″ (0.0178m to 0.610m)
- QD-4000 Servo Amplifier
- Connector options are available; contact Nutfield Technology for more information
Downloads
Documentation for the QS-3 OPD Galvanometer Scanner:
- Nutfield Technology’s OPD Galvanometer Scanners Data Sheet
U.S. patents apply to this product. For details, visit our Virtual Patent Marking page.
Need help choosing the right scanning solution?
Contact Nutfield Technology for assistance with identifying a solution for your scanning application.